



NEW ROOF
IN PROGRESS


CR600 STRAPS USED
INTERNALLY TO
STABALISE A
CORNER JUNCTION
|
DAMP PROOFING
Rising damp is not the most common form of dampness encountered in buildings; this is left to condensation. However, it is very likely that a high proportion of older buildings are affected by rising damp to some degree or another, and it does cause problems with positive identification,
appropriate remedial action and ancillary works.
At DPR we know that many other surveyors for other companies and bank/building society surveyors fail to diagnose rising dampness correctly and therefore instigate a new damp proof course where one is not required thus unnecessary upheaval and expense to the home owner. DPR will only install a damp proof course where it is required.
Other dampness forms like condensation, lateral and penetrating damp will be diagnosed correctly and the necessary action put forward.
RISING DAMPNESS
Rising damp in buildings may be defined as the vertical flow of water up through a permeable wall structure, the water being derived from ground water. The water rises through the pores (capillaries) in the masonry by a process loosely termed ‘capillarity’. In other words the masonry acts like a wick.
The height to which the water will rise depends on several factors including pore structure and rate of evaporation. Masonry containing a high proportion of fine pores will allow the water to rise higher than a coarse pored material; basically the water is carried up the wall in the finer pores and not those of large diameter. The average size of pores in masonry gives a theoretical rise of around 1.5 meters but where evaporation is severely retarded, for example by the use of impervious membranes, moisture can sometimes rise in excess of 2 metres.
The major paths through which the water rises are the mortar beds; For water to rise through the bricks then it must cross a mortar bed. In effect the mortar beds form the only continuous pathways for water rising through the wall. If a house is built from impervious bricks then water can still rise through the mortar bed but if an impervious mortar is used then no water will rise even if the bricks are very porous. The mortar beds will form an important part in the chemical treatment for rising dampness.
GROUND WATER
Ground water also contains small amounts of soluble salts, the most significant of which are chlorides, nitrates and sulphates.
These pass with the water in solution up the wall and are left behind when the water evaporates. Over many years of active rising dampness large quantities of these salts accumulate within the masonry and decorative surface, most becoming concentrated in a general ‘salt band’ towards the maximum height of rise Frequently, the concentrations of these salts are very low towards the base of the wall.
Both chlorides and nitrates are usually hygroscopic, i.e. they can absorb moisture from the surrounding environment and, in general, the greater the amount of salts the greater the absorption of moisture especially under humid conditions.
Thus, even though rising dampness may have been controlled by the insertion of a remedial damp-proof course these salts alone can cause the wall and any contaminated decorations to remain damp.
DAMP-PROOF COURSE
Therefore, to provide a ‘dry’ wall and a suitable surface to take new decorations the new damp proof course system (Dryzone or Tri-Gel) involves two fundamental processes:
1. The insertion of the chemical damp-proof course by DPR operatives.
2. Removal of old contaminated plasterwork/decorations by DPR operatives and replacing with specialist replastering to prevent the passage of any residual moisture and contaminant salts from passing to the new surfaces from the underlying masonry.
ROOFING
PROPERTY RENOVATION & STRUCTURAL SERVICES
DPR carries full public liability insurance for your protection should the unexpected happen.
DPR will agree dates with you and stick to them as far as we possibly can. The main uncertainty is the weather. Naturally you will not want your roof stripped off during heavy rain or high winds.
Our prime concern is the health and safety of yourself and our team. If bad weather delays work, we will talk to you and agree revised dates as soon as possible. Please be assured that, once we start work, your roof will be protected at all times. If we have stripped the roof covering but not finished the replacement, we will put fully weather-proof tarpaulins and other measures in place to prevent any leakage.
In a worst case scenario, such as a severe storm, we provide a 24-hour emergency call out service. We can generally give a start date within a few weeks.
Home owners and small businesses are DPRs main customers, so we will not have to 'fit you in' around other projects. We can do emergency remedial work very quickly if this is needed at a nominal charge.
Planning permission is not normally needed for roofing projects, unless you are in a conservation area or the property is a listed building. Buildings regulations is now mandatory for re-roofing work. Forms should be obtained from your local authority.
Guarantees for roof work vary. New roofs are guaranteed for ten years and will have a manufacturers twenty five year product guarantee also. Repairs are guaranteed for one year which is long enough to confirm the repair has been successful having gone through the very unpredictable British seasons.
Built up felt roofs (flat roofs) are guaranteed for five years but usually have a lifespan in excess of twenty years dependent on location and surroundings. Please note that naturally we can not be held liable for storm damage as this is obviously beyond our control. Your insurance company will assist in the event of storm damage requirements whereby DPR will correct the damage very quickly.
DPR also specialise in Structural Engineer assistance and can specify corrective measures to combat property movement. We can install the latest in structural strapping, lintels, wall re-building and stabilisation.
We at DPR have a client database of property investors whom we carry out full property refurbishment for. This will involve taking the keys to a near derelict home and handing them back, usually within 4-5 weeks, after full refurbishment right down to the carpets and curtains if need be.
We will arrange on your behalf all the sub-contactors whom we know and trust giving you peace of mind that all works come under the DPR umbrella and save you the hassle of shopping around for what could be potential cowboy contractors.
WALL TIE REPLACEMENT
CORROSION OF CAVITY WALL TIES - WHY?
Prior to 1978, wall ties were usually manufactured from galvanized mild steel. These ties were expected to last the lifetime of the building, but for many years it has been recognised that some of these wall ties have corroded after only 15 or 20 years.
When these ties corrode, they can expand to seven times their original thickness. This causes the brickwork to crack at the mortar joints and can result in major damage and sometimes the collapse of walls.
The cavity wall was introduced into buildings because it is the greatest of all damp precautions, water cannot travel across a void. Most masonry is porous to some degree, and sooner or later, especially with weak, or incorrectly constructed joints, that masonry will let in water.

Typical new wall tie for domestic property use. Patented shear
nut design means fast installation which keeps costs down for
the client.
Without a barrier of some kind, there is a chance that water will work its way indoors, however thick the wall. By inserting a cavity, that scenario is impossible. For a number of reasons that we will explain below, the cavity has to be bridged. That is the two leaves, or skins, of the wall have to be connected.
The first thing we see as we look in to the cavity is a wall tie, this is necessary to "tie" the two halves of the wall together and stop one moving independently of the other. If corrosion is found then replacement is the only solution. If corrosion is found on wire twist ties then the solution is much easier as these do not have to be isolated due to their ‘fragile’ nature.
Wire twist ties, generally, do not have the ability to lift and fracture the outer mortar bed joint and thus just simply corrode away to nothing. The more common fishtail type ties have the ability to expand to seven times their original thickness and thus cause structural damage to the mortar joints, sometimes even de-stabilise a wall to the point of collapse under wind loading.
New ties are installed through brick centres at a pre-determined pattern per Sq metre (normally 5 ties per Sq m). Isolation is carried out by cutting back the existing tie in to the cavity and enveloping it in a sleeve or expandable foam so as no further damage can occur from the tie.
|
|